INSTALLATION INSTRUCTIONS
FOR EXCLUSIVE USE WITH THE HURRI-BOLT TOP PLATE TIE-DOWN SYSTEM SBCCI #9910A


    DRILL HOLE

  • Using a Standard Masonry Bit, drill a hole into the concrete to a depth of at least 7-1/2”.


    CLEAN HOLE

  • Blow the hole clean of dust and other material.

  • Insert the anchor through the sill plate and washer into the anchor hole.

  • Thread a Hurri-Bolt Coupler onto the anchor.


    DRIVE ANCHOR

  • Begin tightening the anchor by applying forward pressure when engaging the first few threads.

  • Continue tightening the anchor until the coupler is firmly seated against the sill plate washer.
  • Use of an impact wrench is recommended.

    COMPLETE ASSEMBLY

  • The Hurri-Wedge installation is now complete.

  • Install remaining Hurri-Bolt components.

US PATENT NUMBER #6,367,205

Hurri-Bolt, Inc.
10704 N46th Street Tampa, FL 33617