DESIGNING WITH THE HURRI-BOLT TOP PLATE SYSTEM


FRONT


LEFT


REAR


RIGHT


Typical House Layout

SPECIFYING HURRI-BOLT

  • Install one Hurri-Bolt per leg of each corner.
  • Install one Hurri-Bolt at each
    end of headers over 6 feet.
  • Install Hurri-Bolts every 6 feet in exterior walls.
  • Install Hurri-Bolts every 6 feet in interior truss bearing walls and in each end.
  • Install at each end of shearwalls.

 

Material List

Quan

Part #

Description

24

HBA

Hurri-Bolt Anchors

4

HBE

Hurri-Bolt Epoxy Stud

1

HB10

10oz. Hurribolt Epoxy

28

HBSS

Hurri-Bolt Square Sill Washer

56

HBN

Hurri-Bolt 1/2" NC Nut

49

HBR

Hurri-Bolt 6' Double-End Studs

77

HBC

Hurri-Bolt Couplers

28

HBT

Hurri-Bolt 6' All Thread Top Rods

28

HBST

Hurri-Bolt Square Top Plate Washer


NO STRAPS OR STRAP NAILS BELOW THE TOP PLATE!*

*Most Cases. A combined uplift and shear load analysis should be done to determine if additional sill plate anchors are required.

Spacing determined by the uplift resistance requirement for your structure and rigidity of wall sheathing materials and framing.

Hurri-Bolt Top Plate Capcities

SYP Top Plates, (Fc) = 565 psi

Square Washer Size

2.00

2.50

Rod Size (in.)

Hole Diam.(in.)

(lbs. Uplift)

(lbs. Uplift)

1/2

9/16

2522

3900

 

Hurri-Bolt Tie-Down Capacities per Truss

(S-Y-P Top Plate, Trusses @ 24" Spacing)

Rod Size

(in.)

Washer Size

(in.)

Rod Spacing

48"

64"

72"

(lbs. Uplift)

(lbs. Uplift)

(lbs. Uplift)

1/2

2"

1261

945

840

1/2

2-1/2"

1950

1462

1300